iGas R-404A Refrigerant is a professional-grade refrigerant supplied in a 24 lb factory-sealed cylinder for servicing compatible commercial refrigeration systems.
R-404A is an HFC refrigerant blend widely used in existing low- and medium-temperature refrigeration equipment. This iGas 24 lb R404A cylinder is a practical choice for refrigeration technicians, HVAC-R contractors, facility maintenance teams, foodservice businesses, cold-storage operators, and other qualified commercial buyers maintaining equipment designed for R-404A.
Always confirm the refrigerant specified on the equipment nameplate and follow the equipment manufacturer's service procedures before charging or servicing any refrigeration system.
Brand: iGas
Refrigerant: R-404A
Cylinder size: 24 lb
Condition: New, factory sealed
Refrigerant type: HFC blend
Composition: R-143a / R-125 / R-134a
Safety classification: A1
Ozone depletion potential: 0
EPA GWP reference value: 3,922
Typical lubricant: POE
Primary use: Compatible low- and medium-temperature commercial refrigeration systems
Purchase requirements: Applicable EPA refrigerant sales restrictions apply
R-404A has been used extensively in commercial refrigeration equipment across supermarkets, convenience stores, restaurants, foodservice operations, cold-storage facilities, and other temperature-controlled environments.
Common R-404A applications include walk-in freezers, reach-in freezers, refrigerated display cases, supermarket refrigeration systems, ice machines, cold-storage equipment, transport refrigeration, and other systems specifically engineered for R-404A.
The application alone does not determine compatibility. Always verify that the equipment is designed for R-404A before adding refrigerant.
For refrigeration professionals who regularly maintain R-404A systems, this iGas 24 lb R404A refrigerant cylinder provides a convenient quantity for service, maintenance, and repair work.
iGas R-404A is a blended HFC refrigerant composed primarily of R-143a and R-125 with a smaller percentage of R-134a.
It was developed for low- and medium-temperature refrigeration applications and has zero ozone depletion potential. R-404A also carries an A1 safety classification under the applicable refrigerant safety standard.
R-404A has a relatively high global warming potential compared with many newer-generation refrigerants. As a result, the refrigeration industry continues to transition toward lower-GWP options for many new systems.
Existing refrigeration equipment, however, should continue to be serviced according to the refrigerant specifications and procedures provided by the equipment manufacturer.
R-404A continues to play an important role in servicing the installed base of commercial refrigeration equipment designed for it.
While regulations and equipment standards are driving the adoption of lower-GWP refrigerants in newer refrigeration systems, existing equipment may continue to require R-404A during maintenance and repair.
Technicians should not replace R-404A with another refrigerant solely because a newer alternative is available. Any refrigerant conversion should follow an approved retrofit procedure and take the equipment manufacturer's requirements into account.
R-404A, R-448A, and R-449A are different refrigerants and should not be treated as interchangeable.
R-448A and R-449A are lower-GWP refrigerants used in certain applications where R-404A has historically been used, but compatibility depends on the specific equipment and retrofit requirements.
Changing refrigerants may require evaluation of system controls, expansion devices, lubricant, operating pressures, refrigerant charge, and manufacturer recommendations.
Never mix R-404A with another refrigerant. Use only the refrigerant specified for the equipment unless an approved retrofit procedure states otherwise.
R-404A has an A1 safety classification, meaning it is classified as lower toxicity and does not propagate flame under the applicable refrigerant safety classification system.
It is still stored as a liquefied gas under pressure and requires appropriate professional handling.
Technicians should follow the iGas Safety Data Sheet, equipment manufacturer instructions, and all applicable federal, state, and local requirements for refrigerant charging, recovery, transportation, storage, and disposal.
Appropriate protective equipment and refrigeration service tools should be used whenever handling R-404A.
EPA refrigerant sales restrictions apply to R-404A intended for stationary refrigeration equipment.
For stationary refrigeration and air-conditioning applications, purchasers generally must be EPA Section 608 certified technicians, qualifying employers or authorized representatives of certified technicians, or other purchasers permitted under applicable EPA regulations.
Buyers should confirm that they meet the applicable certification or resale requirements before ordering refrigerant.
Royal Refrigerants supplies HVAC-R professionals, refrigeration contractors, facility teams, and commercial buyers with refrigerants for a wide range of cooling applications.
If you are looking for iGas R404A refrigerant for sale, this factory-sealed 24 lb cylinder provides a branded option for servicing compatible commercial refrigeration equipment.
Royal Refrigerants combines decades of refrigerant-industry experience with competitive pricing, knowledgeable product support, nationwide order fulfillment, and bulk purchasing options for larger commercial requirements.
Confirm that your refrigeration equipment specifies R-404A and review applicable EPA purchasing requirements before ordering.
Shop iGas R-404A Refrigerant Gas in a 24 lb factory-sealed cylinder from Royal Refrigerants for professional service of compatible commercial refrigeration systems.