$365.00
Chemours Opteon™ R-448A Refrigerant is a professional refrigeration solution supplied in a 25 lb cylinder for compatible low- and medium-temperature commercial refrigeration systems. R-448A is an HFO/HFC refrigerant blend developed...

FREE
SHIPPING

100% MONEY
BACK GUARANTEE

ONLINE
SUPPORT 24/7

Availability: Out Of Stock
View Safety Data Sheet
Please confirm by checking the checkbox above.

Chemours Opteon™ R-448A Refrigerant is a professional refrigeration solution supplied in a 25 lb cylinder for compatible low- and medium-temperature commercial refrigeration systems.

R-448A is an HFO/HFC refrigerant blend developed as a lower-GWP alternative to refrigerants such as R-404A and R-507A in approved commercial refrigeration applications. It is commonly used by refrigeration contractors, supermarket service teams, cold-storage operators, foodservice facilities, and other commercial buyers maintaining equipment designed or properly retrofitted for R-448A.

This Chemours Opteon R-448A cylinder provides a branded option for professional refrigeration service where R-448A is specified.

Always confirm refrigerant compatibility with the equipment manufacturer and follow approved service or retrofit procedures before charging a system.

Chemours Opteon R-448A Product Details

  • Brand: Chemours

  • Product line: Opteon™

  • Refrigerant: R-448A

  • Cylinder size: 25 lb

  • Refrigerant type: HFO/HFC zeotropic blend

  • Composition: R-32 / R-125 / R-134a / R-1234yf / R-1234ze(E)

  • Safety classification: A1

  • Ozone depletion potential: 0

  • EPA 100-year GWP reference value: 1,386

  • Typical lubricant: POE

  • Primary applications: Compatible low- and medium-temperature commercial refrigeration

  • Common retrofit applications: Certain R-404A and R-507A systems when approved

  • Purchase requirements: Applicable EPA refrigerant sales restrictions apply

R-448A Refrigerant for Commercial Refrigeration

R-448A is primarily associated with low- and medium-temperature commercial refrigeration.

Depending on equipment specifications and manufacturer approval, applications may include supermarket refrigeration racks, refrigerated display cases, walk-in coolers and freezers, cold-storage facilities, food-processing refrigeration, convenience-store refrigeration, and other commercial systems engineered for R-448A.

R-448A is particularly relevant for businesses and refrigeration professionals seeking a refrigerant with substantially lower global warming potential than R-404A while maintaining existing commercial refrigeration equipment or planning an approved retrofit.

Application type alone does not establish compatibility. Always confirm that R-448A is approved for the specific system before use.

What Is R-448A Refrigerant?

R-448A is a zeotropic refrigerant blend containing R-32, R-125, R-134a, R-1234yf, and R-1234ze(E).

Its standard composition is approximately 26% R-32, 26% R-125, 21% R-134a, 20% R-1234yf, and 7% R-1234ze(E).

R-448A has zero ozone depletion potential and an A1 safety classification. It also has a significantly lower global warming potential than R-404A.

Because R-448A is a zeotropic blend, technicians must account for temperature glide when evaluating pressures, temperatures, superheat, subcooling, and charging procedures.

Professional service personnel should use current R-448A pressure-temperature data and follow equipment manufacturer instructions.

Chemours Opteon R-448A vs. Honeywell Solstice N40

Chemours Opteon R-448A and Honeywell Solstice® N40 carry the same R-448A refrigerant designation.

R-448A is defined by its standardized refrigerant composition, so properly specified R-448A products use the same refrigerant blend regardless of the brand supplying the cylinder.

Honeywell markets its R-448A as Solstice N40, while this product is supplied under the Chemours Opteon brand.

Buyers requiring a particular manufacturer or brand should always verify the cylinder label before purchasing.

Do not confuse Chemours Opteon R-448A with Opteon XP40. Opteon XP40 is R-449A, which is a different refrigerant formulation.

Can R-448A Replace R-404A or R-507A?

R-448A is used as a replacement refrigerant in certain commercial refrigeration systems originally designed for R-404A or R-507A, but it should not be described as a universal drop-in replacement.

A proper retrofit requires professional evaluation of the refrigeration system and manufacturer requirements.

Technicians may need to consider equipment compatibility, compressor requirements, POE lubricant condition, refrigerant charge, expansion valves, control settings, pressure-temperature relationships, temperature glide, and system operating conditions.

The original refrigerant should be properly recovered before the approved replacement refrigerant is introduced.

Never mix R-448A with R-404A, R-507A, R-449A, or another refrigerant.

R-448A vs. R-449A

R-448A and R-449A are similar commercial refrigeration refrigerants, but they are not the same product.

Both are A1 HFO/HFC blends used in certain low- and medium-temperature refrigeration applications, but their chemical compositions differ.

Chemours Opteon XP40 is R-449A. R-448A contains an additional R-1234ze(E) component and has its own standardized composition and pressure-temperature characteristics.

Technicians should always use the exact refrigerant specified or approved for the equipment rather than treating R-448A and R-449A as interchangeable.

Lower GWP Than R-404A

R-448A has an EPA 100-year GWP reference value of 1,386, compared with 3,922 for R-404A.

That represents a substantial reduction in refrigerant-related global warming potential compared with R-404A.

However, environmental impact depends on more than the refrigerant's GWP. Refrigerant charge, leakage, system efficiency, maintenance, equipment design, and operating conditions also affect the overall environmental performance of a refrigeration system.

For that reason, R-448A should be described as a lower-GWP alternative to R-404A rather than as environmentally harmless or universally sustainable.

R-448A Safety and Professional Handling

R-448A carries an A1 safety classification, meaning it is classified as lower toxicity and does not propagate flame under the applicable refrigerant safety classification standard.

It is still a liquefied gas under pressure and requires appropriate professional handling.

Technicians should follow the Chemours Safety Data Sheet, equipment manufacturer instructions, approved retrofit guidance, and applicable federal, state, and local requirements for refrigerant recovery, charging, storage, transportation, and disposal.

Professional refrigeration tools, recovery equipment, and personal protective equipment appropriate for the application should be used.

Do not intentionally vent refrigerant into the atmosphere.

Who Can Purchase R-448A Refrigerant?

Federal refrigerant sales restrictions apply to R-448A intended for stationary refrigeration equipment.

Purchasers generally must be EPA Section 608 certified technicians, qualifying employers or authorized representatives of certified technicians, qualifying resellers, or other purchasers permitted under applicable EPA requirements.

Section 609 certification applies to motor-vehicle air-conditioning applications and does not by itself qualify a purchaser to buy refrigerant intended for stationary commercial refrigeration equipment.

Buy Chemours R-448A 25 lb Refrigerant

Royal Refrigerants supplies refrigeration contractors, HVAC-R professionals, supermarket service companies, facility teams, and commercial buyers with refrigerants for a broad range of cooling applications.

If you are looking for Chemours R-448A refrigerant for sale, this 25 lb Opteon cylinder provides a recognized branded option for compatible commercial refrigeration equipment and approved retrofit applications.

Royal Refrigerants combines decades of refrigerant-industry experience with competitive pricing, knowledgeable support, nationwide order fulfillment, and bulk purchasing options for commercial customers.

Order Chemours Opteon R-448A Refrigerant

Confirm that your equipment specifies R-448A or has an approved R-448A retrofit procedure before purchasing.

Check current availability and shop Chemours Opteon R-448A 25 lb Refrigerant from Royal Refrigerants for professional commercial refrigeration applications.

We offer FREE continental US shipping. Most orders are shipped same day or next day by Hazmat Ground. You will receive an email notification with tracking when your order is shipped.
Just added to your wishlist:
My Wishlist
You've just added this product to the cart:
Go to cart page
// James's Codes start--------------------------------------------------------------------- // James's Codes end-----------------------------------------------------------------------